Index values are unchanged (1, 3, 7, 10, 13); the run recorded at fb507aa1
used the same columns. Research-only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Tests load research drivers via importlib under unique module names
instead of a bare 'import run' (shared-process collision between the
Dütsch and VIV drivers). lifecycle.md qualifies immutable geometry and the
host-only get_flags for translating circles; supported_settings.md points to
the dense-only moving-circle feature; leontini_viv_predeclare.md is renamed
viv_re150_predeclare.md (Re 150 Kolahdouz/Qin case) with references updated.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Seed quiet check reads states y_t, t in [n_seed - 5 T_n, n_seed); an
exception sets status 'error: ...' before the report is written; an output
directory that already holds report.json or steps.npy is refused; --max-steps
gives a plumbing smoke that is never scored. Predeclare states the code's
actual uniform-U fluid initial condition.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
viv.py: exact undamped harmonic update under the last completed force,
y = 0 response cycles with eligibility, 10-cycle blocks, settle/score with
deterministic restart, conditional velocity seed, scoring metrics. run.py:
Simulation-API driver (set_body + run(1)), RHS = CME + Wen from the moving
diagnostics, raw CME/obs/node terms logged, fail-closed bounds, caps and
input rejection, outputs outside the checkout. CPU tests for the logic and
the real config loader. Predeclare: stale failure sentence removed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
At the first step of each scored phase bin in the declared cycles, write a
near-body crop (±8D × ±6D, float32 ux, uy, rho + fluid mask), an 8x
fluid-weighted downsample of the whole domain, the same-step force and the
analytic centre; at every bin read, append fluid-mean rho/ux/uy and crop,
inlet- and outlet-strip means to trend.npy. Fail closed if the crop leaves the
domain or clips the swept body. Without --dump-fields nothing changes.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Coverage and no_donor/eq_only totals now stop at the horizon; HF energy
uses one-sided Parseval weights (interior bins x2, DC/Nyquist x1). Focused
regressions for both. run.py, src and thresholds unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Default (no --horizon) keeps the original cap-11 scoring. --horizon N
requires complete cycles 1..N in every case, passes the horizon to
common_window and labels the JSON. The unqualified phase-locked HF force
component is reported per case. Protocol section 6b declares the D40/60D
31-cycle duration-only diagnostic.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The generated config failed the real loader (KeyError: cuda). It now copies
src/CelerisLab/configs/config_lbm.json and overrides only grid, physics,
collision/streaming/storage, y walls, LES off and uniform inlet profile;
inlet scheme and outlet mode stay the template's and are recorded in
case.json. New CPU test loads the generated file with load_lbm_config.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
common_window requires every pair from each case's own K_case to K+2;
a-priori domain criteria against the 60 D reference (separate from Table 1);
bilinear sampling returns the original fluid corner weight sum; analysis
time-averages bin samples, reports coverage/missing points and fails closed
on an empty common profile set; cases run to the end of cycle 11.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
protocol.py holds the pure arithmetic (phase/cycle bookkeeping from the right
turning point, 1-degree bins, interval-averaged Morison bases and fit with
added-mass c_i, solid-aware bilinear sampling, settling and common-window
rules). run.py drives the existing Simulation API (set_body + run(1) +
read_force + moving_diagnostics; macroscopic fields and flags only inside the
three phase bins) and writes raw data outside the checkout. analyze.py builds
the cycle ledger, K_case, the common window, Morison fits, Fy sanity and the
cross-resolution waveform difference. CPU tests cover the §6a arithmetic.
Carries the protocol doc from claude/duetsch-protocol 8c1f3c4d.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>