research: VIV driver reads diagnostics by MovingTables.DIAG name; coupling-contract README
Index values are unchanged (1, 3, 7, 10, 13); the run recorded at fb507aa1
used the same columns. Research-only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
committed by
Frank14f
co-authored by
Claude Opus 5.5
parent
d5b13d7f31
commit
3f7f303e17
@@ -0,0 +1,23 @@
|
||||
# Research VIV driver — coupling contract (not production)
|
||||
|
||||
`run.py` couples a 1-DOF undamped spring–mass (`viv.py`) to the production
|
||||
moving-circle API. Everything specific to fluid–structure coupling lives here,
|
||||
not in `src/`.
|
||||
|
||||
- Per step: known (y_n, v_n) and the last completed force F_last → exact
|
||||
harmonic candidate (y_{n+1}, v_{n+1}) → `set_body(offset=(0, y_{n+1}),
|
||||
vy=y_{n+1} − y_n)` (interval wall velocity, lattice dt = 1) → `run(1)` →
|
||||
commit y, v and F_last only after the step succeeded. One step of explicit
|
||||
force lag (weak coupling); no sub-iteration.
|
||||
- Structural RHS = CME + Wen (y), read from `moving_diagnostics()` by the
|
||||
names in `MovingTables.DIAG`; raw CME, the `obs` force and node terms are
|
||||
logged as diagnostics. This is a stage choice, not a validated force law.
|
||||
- Production guarantees used: fail-closed target commit (synchronized step,
|
||||
`no_donor == 0`), input rejection before mutation, a failed device step
|
||||
marks the Simulation failed.
|
||||
- Not provided, by design: device-resident structure state or batched
|
||||
(multi-step) coupling, strong/sub-iterated coupling (would need state
|
||||
rollback), more than one DOF. These are future work and would be a separate
|
||||
execution path, not an abstraction over this driver.
|
||||
- Recorded result and limits: `docs/validation/moving_bodies_stage1.md`;
|
||||
predeclaration: `docs/validation/viv_re150_predeclare.md`.
|
||||
@@ -65,7 +65,8 @@ def main():
|
||||
step_cap = args.steps
|
||||
centre = (30.0 * Dn, 0.5 * (ny - 1))
|
||||
|
||||
from CelerisLab.body.motion import Translation
|
||||
from CelerisLab.body.motion import MovingTables, Translation
|
||||
col = {k: MovingTables.DIAG.index(k) for k in ("cme_y", "wen_y", "cover_jy", "uncover_jy", "no_donor")}
|
||||
from CelerisLab.simulation import Simulation
|
||||
with tempfile.NamedTemporaryFile("w", suffix=".json", delete=False) as fh:
|
||||
json.dump(cfg, fh)
|
||||
@@ -95,9 +96,9 @@ def main():
|
||||
sim.run(1) # device failures raise and mark the Simulation failed
|
||||
d = sim.moving_diagnostics()[0]
|
||||
f_obs = sim.read_force(body)[1]
|
||||
f_rhs = float(d[1] + d[3]) # CME + Wen (y)
|
||||
row = (n, y1, v1, f_rhs, float(d[1]), float(d[3]), float(f_obs),
|
||||
float(d[7] - d[10]), float(d[13]))
|
||||
f_rhs = float(d[col["cme_y"]] + d[col["wen_y"]]) # CME + Wen (y)
|
||||
row = (n, y1, v1, f_rhs, float(d[col["cme_y"]]), float(d[col["wen_y"]]), float(f_obs),
|
||||
float(d[col["cover_jy"]] - d[col["uncover_jy"]]), float(d[col["no_donor"]]))
|
||||
if not viv.finite(row): # every recorded output, not only the RHS
|
||||
status = "fail_nonfinite_output"
|
||||
break
|
||||
|
||||
Reference in New Issue
Block a user