52 lines
8.2 KiB
Markdown
52 lines
8.2 KiB
Markdown
# MeltMind research tree (Claude maintains it, single writer; started 2026-11-17)
|
|
|
|
Method (Yanqi): explore many branches; none has to succeed. Each branch gets a cheap gate, learns something and is pruned or expanded. Every probe, counter-example and prune reason is kept here. Goal: state-of-the-art fill prediction.
|
|
|
|
Rules:
|
|
- A branch starts with a **gate**: the cheapest test that could prune it (about 2 CPU-h or less, or existing outputs only). Gate criteria are written down before the run.
|
|
- Statuses: OPEN, PROBING, PRUNED (with reason), PROMOTED (gets a contract), PARKED.
|
|
- Every result records what we learned, even when the result is negative.
|
|
- At most 2 promoted branches run at a time; gates can run in parallel on free cores.
|
|
- Single writer per execution root (MeltAstra on Horsea). One review from Claude per contract.
|
|
|
|
| ID | Branch | Gate (cheapest falsifier) | Owner | Status |
|
|
|---|---|---|---|---|
|
|
| B1 | H1: residual on the eikonal volume map (t* - cF, same 19 features) | full run is cheap (<= 20 CPU-h) | spec Mold, run Melt | PROMOTED |
|
|
| B2 | H2: geometry-aware operator on the H1 target | pilot <= 2 GPU-h with a cost gate | spec MeltAssist, run Melt | PROMOTED (after the B1 contract) |
|
|
| B3 | Arrival-field topology: dry-region H0(-T) maxima and saddles as last-fill / front-meeting diagnostics | on about 50 parts, compute the diagnostics from the true T and from the full-node EIK; check whether they are stable and whether EIK's critical points match the truth | spec Mold, run Melt | OPEN |
|
|
| B4 | Filling as a filtration: one scalar potential plus a monotone time map | oracle: the best per-part monotone map from the EIK potential to the true T; the remaining error is ordering error that no time map can fix | Mold / Melt | PRUNED (clock-only on a fixed potential cannot beat A) |
|
|
| B5 | Sheet / paired-wall decomposition on real meshes | scope a relaxed general-domain certificate on paper; then try 10 Greif parts and report coverage and false connections | Mold, then Melt | PARKED (coverage unknown: certifier complexity cap) |
|
|
| B6 | Intrinsic coordinates (Laplace-Beltrami / spectral) as features | 50 parts: does a spectral feature explain A's residual (partial correlation on the learning folds only)? | MeltAssist lit, Melt run | OPEN |
|
|
| B7 | Order-aware objective (pairwise or rank loss) instead of pointwise L2 | small GBRT ranker on one fold: Kendall tau and last-fill location against A | MeltAssist / Melt | OPEN |
|
|
| B8 | Fresh hold-out from Greif v2 (42 parts, 40 new source tokens) | read-only LOG/YML, field validity and near-duplicate check | MeltAssist | PARKED (missing process provenance: v2 ZIP has 723 VTU and 0 LOG/YML, so no t_set) |
|
|
| B9 | Heat transfer / packing targets (cooling time, shrinkage) | read-only inventory of v4/v5 fields | MeltAssist | DONE (inventory) → opens B10 |
|
|
| B10 | Freeze time / volumetric shrinkage as targets with the same Gre24-style pipeline (Yanqi: fill first, so low priority) | gate: per-field validity (units, stage, mask) on 20 parts, then a Gre24-style GBRT on one fold against Gre24's reported medians (cooling about 0.095, shrinkage about 0.10) | Melt / MeltAssist | PARKED (priority) |
|
|
| B11 | Topological cleaning of predicted fields: persistence simplification removes spurious extrema and saddles before the end-of-fill and event metrics | gate: on the B3 panel, apply a fixed persistence threshold to EIK, and later to the A/H1 full-node predictions, and check event precision, last-fill distance and tau (learning folds only) | Mold spec, Melt run | OPEN |
|
|
| P1 | O2 local tensor readings | — | — | PRUNED (S1, S2, S3-A: no gain on the current recipe) |
|
|
| P2 | Own graph flow-competition solver | — | — | PRUNED (infeasible: splu resource stop, GMRES numerical failure; the idea itself is untested) |
|
|
| P3 | O1 with size-matched K = 8 partitions | — | — | PRUNED (eligibility 23 %; lesson: control cut area as a covariate, do not match it) |
|
|
|
|
Log (newest first):
|
|
- 2026-11-17: **B5 PARKED (coverage unknown).** On 10 learning parts, 5 had no candidate; on the other 5, the first candidate hit the fixed 70000-operation complexity cap and came out UNKNOWN. 0 certified and 0 rejected; only 5/10 parts have a certified union that is complete and below .20, short of the >= 6/10 threshold.
|
|
- **Learned:** the relaxed paired-wall certifier is computationally infeasible on real Greif meshes at this cap. That is not a refutation of sheet decomposition.
|
|
- Reopen only with a new certifier design (no cap extension under this gate). Cost 133.7 CPU-s. Commit 6aa7baf6.
|
|
- 2026-11-17: B1 first-cell cost gate PASS (fit projection 3610 CPU-s); fits 01-04 running.
|
|
- 2026-11-17: **B3 result** (50 learning components):
|
|
- The true-field H0(-T) events are stable under recording-precision perturbation: precision/recall .954/.921 (0.001 grid) and .947/.915 (half grid), above the 0.80 gate.
|
|
- EIK against the truth: 244 TP, 16956 FP, 416 FN, so precision .014 and recall .370; median match distance .049 Rg.
|
|
- **Learned:** the eikonal field has a very large number of spurious topological events. This supports a stable diagnostic on this panel; it is not a weld-line validation.
|
|
- New branch B11 (topological cleaning).
|
|
- 2026-11-17: **B4 PRUNED (clock-only).** The post-hoc best monotone map of the fixed D_f potential gives a component-mean relative L2 of .0916, against A's .0664 on the same full-tet domain.
|
|
- **Learned (narrowed per MeltAstra):** A is not a member of the family of monotone scalar clocks on this fixed D_f, so that family alone cannot explain A's advantage. It does not attribute the advantage solely to order changes.
|
|
- This does not prune new potentials, branch information or learned ordering. Commit a6998f72; push pending.
|
|
- 2026-11-17: B1 contract e751e5b2 approved. **Branch decision rule** (grouped protocol, 100 % pool, paired component bootstrap, signs as H1 - A):
|
|
- EXPAND: upper bound of the relative-L2 difference < 0.001, **and** either the last-fill distance/Rg difference has its upper bound < 0 or the Kendall tau difference has its lower bound > 0.
|
|
- PRUNE: lower bound of the relative-L2 difference > 0 **and** neither of those improves clearly.
|
|
- PARK otherwise.
|
|
- Topology metrics and v4 results are descriptive only.
|
|
- B8/B9 publication fixed at 1153cd8c.
|
|
- 2026-11-17: B9 full-library schema scan (MeltAssist; 1253/1253 files parsed, 0 failures, no numeric decoding). Freeze_time and shrinkage are present in every v4 and v5 part. Temperature, pressure, velocity and deflection are present in 621 of 629 v4 parts (the 8 missing ones are listed) and in all 624 v5 parts. Trajectories have 99 to 110 frames. v5 also carries cell residual stress. This shows the schema exists; the values have not yet passed any eligibility check. Opened B10 as PARKED, behind fill-time priority.
|
|
- 2026-11-17: B8 PARKED (MeltAssist; 4 Range reads, 77,714 B). Reopen if the companion LOG/YML is obtained or the VTU carries equivalent pre-solve metadata. **Narrower reopen path (Claude):** the 42 parts may still serve as a fresh hold-out for *scale-free* metrics only (Kendall tau, last-fill location, H0(-T) events), which need no t_set. They then need only field validity and the near-duplicate check, not process provenance. **Narrowed by MeltAssist:** the models still need the gate as an input, through D_i, D_f and F. Scale-free scoring is therefore not gate-free inference. Without equivalent metadata in the VTU or an original gate source, reopening needs a separate task built only from the available fields; recovering the gate from the minimum of the true T would be label leakage.
|
|
- 2026-11-17: MoldAstra B1 short spec + H0(-T) metric (Drive 1WHFdSP7…, SHA 91ecc62f…); one-page maths judgement (Drive 1I_H_UxU…: an order-preserving clock change cannot move ranking events; in a simplified constant-pressure counter-example, along-path loading gives a 4x fill-time difference that vanishes at constant flow); gate specs for B3/B4/B5 (Drive 1LUaoJn9…) approved as written. MeltAstra B1 contract draft 0a60f5d6 plus a one-page physics finding (gate reachability and early wet islands are more direct than wet-region H0 merges; the volume quantile is a shared progress variable, not the full hydraulic state). B3/B4/B5 move to PROBING once the B1 contract is frozen.
|
|
- 2026-11-17: tree started; B1/B2 promoted on Yanqi's approval; B3-B9 opened.
|