WIN-TEST-SELECT v1.1: mirror of AGY v1 with gate and flow-rate corrections
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
6300cb7312
commit
d1d59292a3
1 file changed
+37
@@ -0,0 +1,37 @@
|
||||
# New Windows Complex-Geometry Test Set — Selection Rule (`WIN-TEST-SELECT-v1.1`)
|
||||
|
||||
Mirror by Claude of AGY's `WIN-TEST-SELECT-v1` (`agy/win-test-select-v1` @ 3db1079f, `docs/win-test-select-v1-2026-11-23.md`, SHA-256 c6c81daa…, not yet pushed), with **two corrections** from Claude's ruling of 2026-11-23 (after the Greif §2 / v5 data-card source check). Text otherwise follows AGY v1; §5 strata/backup wording is taken from AGY's v0 post because the v1 Slack copy was truncated there. This file is NOT byte-identical to AGY's.
|
||||
|
||||
- **Stage boundary:** test-only. No part ever enters training, standardisation, clock fitting or tuning. Nothing runs until Yanqi confirms `N` (10–20) and the frozen manifest SHA-256 is recorded.
|
||||
|
||||
## 1. Source pool, feasibility gate, shared mesh
|
||||
- Pool: public ABC CAD, chunk slice `0000–0009`, sorted by 8-digit ABC ID and hashed before sampling; exclude all Greif v5 (624), v4 (629) and Zenodo 17831586 (196) parts (ABC ID and 24-char family prefix). Too few candidates → extend by the declared next slices (`0010–0019`, …); never loosen a threshold after seeing candidates.
|
||||
- Hard gate with logged reason codes (`DISCONNECTED`, `NON_MANIFOLD`, `OUT_OF_SCALE`, `TOO_THIN`, `MESH_FAIL`): one connected watertight manifold solid; bbox max 20–250 mm; volume 1–300 cm³; 2·P50(Dw_int) ∈ [0.8, 6.0] mm; min thickness ≥ 0.5 mm.
|
||||
- One shared BDF mesh per part from a fixed Greif-like-density recipe (5,000 ≤ nodes ≤ 120,000, all tets positive); Moldex3D imports that exact BDF (as in Run 02); v3.1 element→original-ID mapping applies. Recipe and every BDF SHA-256 in the manifest.
|
||||
|
||||
## 2. Gate placement (CORRECTED)
|
||||
- Source: Greif et al. §2 (OPUS 113920) and the v5 data card (Zenodo 18598121): one random node of the Gmsh surface mesh; no published seed, weights or thickness filter.
|
||||
- Rule: all exterior surface nodes, **no thickness restriction** (AGY v1 had "≥ median thickness"; withdrawn to stay with Greif's documented distribution). Sort by original node ID; draw one node uniformly with `PCG64(SeedSequence([2026112301, abc_id]))`.
|
||||
- Manifest label: "seeded uniform random surface node — same documented rule as Greif, not a value-wise replica of Greif's undocumented draw".
|
||||
|
||||
## 3. Complexity criteria (geometry only; anchors from Greif fold-0 learning only, frozen before scoring)
|
||||
- C1 thickness contrast: R_th = P90(Dw_int)/P10(Dw_int) ≥ max(2.5, P75_learn).
|
||||
- C2 path tortuosity: τ = max(Di)/‖x(argmax Di) − x_gate‖ ≥ max(1.35, P75_learn).
|
||||
- C3 multi-branch: ≥ 2 local maxima of Di separated by geodesic ≥ .25·max(Di) (or ≥ 2 superlevel components at .75·max(Di)).
|
||||
- C4 topology / flow-vs-geometry divergence: genus g ≥ 1, or 1 − Spearman(Di, Df) ≥ P75_learn.
|
||||
- Eligible: ≥ 2 of C1–C4.
|
||||
|
||||
## 4. Near-duplicate exclusion (vs Greif v5, v4, 17831586 and already selected parts)
|
||||
- Stage 1: inertia ratios, V/V_OBB, A³/V², genus, 20-bin D2 histogram (4,096 points, Rg = 1); pairs with L1(D2) < .12, inertia L∞ < .10 and equal genus go to stage 2.
|
||||
- Stage 2: 24 PCA symmetries + bounded ICP; reject if Chamfer < .05 Rg or Hausdorff-95 < .12 Rg (log .05–.08 Rg); reject shared document family IDs.
|
||||
|
||||
## 5. Draw protocol
|
||||
- Permute the hashed pool once with `PCG64(SeedSequence(2026112301))`; walk in strict order, no backtracking or manual swaps.
|
||||
- Four equal strata: (1) C1 with g = 0; (2) g ≥ 1 with C2 or C4; (3) C2 + C3; (4) ≥ 3 of C1–C4. Full stratum → later matches logged `STRATUM_FULL` and skipped.
|
||||
- Pre-draw a 5-part backup list in queue order, used only to replace a part failing Moldex3D meshing/convergence (reason logged).
|
||||
|
||||
## 6. Process recipe, host, reporting (CORRECTED)
|
||||
- Screening on Horsea; Windows runs Moldex3D only on the frozen BDF manifest.
|
||||
- **Process:** Greif let Moldflow choose the flow rate per geometry, so a fixed 0.05 s for all parts would not match. Use **Moldex3D's automatic injection-time setting if available**; otherwise a fixed rule written down before any solve. 270 °C melt / 45 °C mould; V/P recorded; material Celstran PP-GF30-03 (substituted). Name: "Windows test recipe", never "same condition as Greif". Record each part's actual fill time; **normalised arrival time is the primary comparison**.
|
||||
- Freeze and hash the manifest (BDFs, gate node IDs, strata, backup queue, exclusion log, mesh and process recipes) before any solve or model forward pass; read each Moldex3D output once at evaluation.
|
||||
- Label: "complex-part test set (≥ 2 of C1–C4), Windows test recipe, cross-solver, material substituted"; report per stratum and overall; do not compare directly with Greif averages.
|
||||
Reference in new issue
Block a user