research-tree: weld lines dropped, persistent late pockets kept

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
ClaudeandClaude Opus 5.5 committed 2026-11-23 08:58:48 +00:00
1 parent 310d3765f1
commit a43cf56dab
1 file changed
+1
+1
View File
@@ -34,6 +34,7 @@ Rules:
| P3 | O1 with size-matched K = 8 partitions | — | — | PRUNED (eligibility 23 %; lesson: control cut area as a covariate, do not match it) |
Log (newest first):
- 2026-11-23: **Derived targets from the arrival field (learning-side checks d136d72e, 69fa252d; truth only, 10 fold-0 learning parts).** Weld-line detector r2 (surface-tangential gradients) removed the thin-wall band (6,314 → 51 nodes) but still marks edges/steps (part 331: 30 segments, 9.1 % of surface) → **weld lines dropped** for Greif; revisit only against Moldex3D's own weld-line output. Air-trap proxy r2 (persistence ≥ 5 % of span, basin ≥ .1 %) cuts 13–28 raw maxima to 0–5 per part; kept peaks can be whole late branches and Greif has no vent/trap truth → **renamed 'persistent late pockets' (topology of the arrival field), not air traps**. Constants frozen as r2; descriptive H2 vs GBRT-19 scoring on used fold 0 after one MoldSol check.
- 2026-11-23: **Transolver vs H2 closed (fill time, prebinding 9e2754f9, used holdouts).** Fold 1 (91/41, terminal 0fbe6166): H2 6.518 %, Transolver s0 6.760 % (+.24 pp [−.19, +.58]), s1 6.555 % (+.04 pp [−.51, +.49]). Fold 0: Transolver +.60 / +.51 pp worse, CIs exclude 0. **Reading:** Transolver (global attention, 197.9K params, 57,898 GPU-s) is not better than H2 on either fold and worse on fold 0. **Ruling:** H2 stays the fill-time model; Transolver not adopted. With pretraining, arm S and Transolver all negative, more architecture variants on the same Greif data are low-value; the next gains need new information (process variation via Moldex3D, validated thickness) or new targets (weld lines/air traps derived from the arrival field).
- 2026-11-23: **Arm S fold 3 + closure.** Fold 3 (113/41, scores 3ff5c8b9) was read by the auto-chain before my hold reached it: S − A P +.90 pp [−6.04, +7.90], T +.12 pp [−.09, +.34] → no pressure gain on fold 3. Arm S over 3 folds: P −7.4 / −11.7 / +.9 pp; T guard failed on all three. **Pressure-level head: not established (does not replicate).** The P-only composite pre-registration is WITHDRAWN (fold 3 already read; fold 4 alone would be a single post-hoc fold); S fold 4 fit cancelled before start. **Next:** measure seed noise of arm A's pressure error (A seed 1 on folds 1–3, descriptive, prebound) so fold-to-fold swings of ±7–12 pp can be read against it before any further P architecture work; a physics pressure-level prior waits for validated thickness.
- 2026-11-23: **Arm S folds 1/2, P/T fold 4, Transolver fold 0 (custody reads 05:40 UTC).** (a) Arm S (pressure scale head) vs frozen A, used P/T holdouts: fold 1 (82/38) P −7.43 pp [−14.92, −.16], T +.02 pp [−.21, +.26]; fold 2 (92/40) P −11.65 pp [−18.62, −5.48], T −.08 pp [−.45, +.39]. Pressure improves on both folds, but the prebound T guard (CI upper ≤ +.20 pp) FAILS on both — by width, not by shift. **S fails its prebound gate**; no re-tuning, no relabelling. (b) Fold 4 A − GBRT-19 (unread P/T holdout, 118 P/T parts, 43 families): P −102.2 pp [−138.4, −72.8], T −.78 pp [−1.19, −.33] → PASS; arm A now passes on 4/4 fresh folds. (c) Transolver vs H2, fold 0 only (used holdout, 121/37): H2 6.747 %, Transolver s0 7.342 % (+.60 pp [+.28, +.93]), s1 7.258 % (+.51 pp [+.11, +.91]) — H2 better on both seeds; fold 1 pending. **Ruling:** pre-register a P-only composite (pressure from S, temperature from A, so T is unchanged by construction) before the fold-3 read: fold 3 primary (P CI upper < 0), fold 4 replication (needs an S fit on fold 4). MoldSol checks the delta once.