31 lines
1.9 KiB
Plaintext
31 lines
1.9 KiB
Plaintext
(2 total) ===
|
||
|
||
--- Reply 1 of 2 ---
|
||
From: ClaudeWorker (local) <botuser-T0C8JMA61UY-B0C7YUHNDFC@slack-bots.com> (U0C7SSQLBJ7)
|
||
Time: 2026-11-14 21:19:16 CST
|
||
Message TS: 1794662356.246479
|
||
Accepted; working on: “MeltAstra 正在实际启动下一阶段校准,已确认无既有校准产物/进程,固定 det/2000面积PPS/全三角双向P95 协议不改。常规…”
|
||
|
||
--- Reply 2 of 2 ---
|
||
From: ClaudeWorker (local) <botuser-T0C8JMA61UY-B0C7YUHNDFC@slack-bots.com> (U0C7SSQLBJ7)
|
||
Time: 2026-11-14 21:19:40 CST
|
||
Message TS: 1794662380.787319
|
||
*Claude: confirmed, with one correction to the physical route*
|
||
|
||
• *Two separate thresholds, as you propose:* τ_phys and τ_sf. Each = 3 × the largest positive-pair residual on its own route, where a pair's residual is min(det+, det−) P95. A pair links if either route, in either branch, is at or below its threshold.
|
||
• *Correction: express the physical route without units as well.* Part volumes span about 5 orders of magnitude, so a single τ in raw units would mean entirely different tolerances for small and large parts. So:
|
||
• *physical residual = P95 in raw units ÷ the mean of the two parts' R_g*;
|
||
• *the physical route also requires an R_g ratio ≤ 1.05.* That keeps it a same-size route.
|
||
|
||
The scale-free route stays as it is (each part normalised by its own R_g).
|
||
• *Positives per route,* as you set them out:
|
||
• physical: rigid copies, mirror copies, and the 2 natural pairs;
|
||
• scale-free: all three copy types (rigid, mirror, 2× scale) plus the 2 natural pairs.
|
||
• *Negative control:* the 2× scaled copies must fail the physical route because of the R_g-ratio gate. Report that they do. If any passes, stop.
|
||
• *Also report:*
|
||
• the full residual distribution of positives per route and branch;
|
||
• for the mirror copies, which branch fits best. det− should win; if it doesn't, flag it, as a check on the implementation.
|
||
|
||
Everything else proceeds as you described under the reproducible contract.
|
||
|