From 5936501c29c9f6d6b6553440e30a26fbdf5cc63d Mon Sep 17 00:00:00 2001 From: Claude Date: Tue, 24 Nov 2026 10:54:06 +0000 Subject: [PATCH] research-tree: Windows round 1 acceptance diagnosis (mid-round) Co-Authored-By: Claude Opus 5.5 --- docs/claude/research-tree.md | 1 + 1 file changed, 1 insertion(+) diff --git a/docs/claude/research-tree.md b/docs/claude/research-tree.md index 62ba20f6c..19875526e 100644 --- a/docs/claude/research-tree.md +++ b/docs/claude/research-tree.md @@ -34,6 +34,7 @@ Rules: | P3 | O1 with size-matched K = 8 partitions | — | — | PRUNED (eligibility 23 %; lesson: control cut area as a covariate, do not match it) | Log (newest first): +- 2026-11-24: **Windows test round 1 (h-3bf4062e), acceptance diagnosis mid-round (no scoring).** Frozen same-mesh manifest 17b7cc1d (12 + 8); blind predictions frozen 6ec4dfa1; prebinding fc8b5570 (MoldSol PASS); v3.2 acceptance (float32 coordinates, boundary-record inlet, ordering start criteria; MoldSol PASS). So far 10 solves + 1 ineligible: **5 PASS** (00006459, 00008628, 00007263, 00009500, 00006054); FAIL: 3 tiny negative arrival times (−0.15 to −6.4 µs; 00004999, 00004398, 00005213), 2 short shots at the solver's filling-time limit (99.7–99.8 %; 00008441, 00002722), 1 fill-end tolerance (0.55 ms > 0.5 ms; 00002750); 1 INELIGIBLE gate on an enclosed cavity (00003959). Stratum 2 has no backups left; one extra stratum-4 part approved by Yanqi (from queue #471). **Reading:** about half the complex parts fail acceptance; the failures are acceptance/solver-setup issues, not model issues, and may correlate with geometry (selection risk). Rules stay frozen this round. **Next-round candidates (decide after the round):** outer-shell gate draw (v1.3); solver max filling time as a fixed multiple of the recipe time; fill-end tolerance tied to the log's print step; negative-time rule informed by where those tets sit (distance to inlet). - 2026-11-24: **Multigate features: K=1 production compatibility PASS (Q6, h-3bf4062e).** AGY `agy/multigate-features` @ a13521af (pushed by Frank from aws-la); Horsea: 5/5 tests, two independent mesh fixtures, all 7 production arrays identical in shape/dtype/byte SHA to the frozen `gre24_features_v2` (receipt f7765d73, per-array 9683de7a). Scope: single-gate compatibility only — no real parts, models, labels or GPU. **Status:** ready; parked until multigate simulation data exists (reopen needs NewMeltAstra's mesh-stability gate as well). - 2026-11-23: **Greif 778 cross-solver supplement (learning part re-read once; arrays 0dbef32c, scores 100626b9).** Raw-seconds relative L2 **22.1 %** (normalised 11.4 %); fill end 59.82 vs 51.00 ms (+8.82 ms, +17 %); last-1 % physical-volume regions: centroid distance **.39 mm = 1.3 % of the diagonal** (the earlier 3.1 mm was a single-max tie artefact). **Reading (one part; V/P differs; material substituted):** the two solvers agree on WHERE the part fills last, differ by ~17 % in total fill time and ~11 % in normalised filling pattern. Not a general solver-disagreement floor; a second part would be needed before using it as one. - 2026-11-23: **Moldex3D route + first cross-solver look (Greif 778, fold-0 learning part).** Single approved Moldex3D Fill solve (Run 02, project's saved condition) → per-element arrival CSV for all 142,306 original tets; checker v3 FAILED on two node-rule carry-overs; v3.1 (gate = inlet-face tets; hard rule = every tet reaches the inlet along a non-decreasing vertex-adjacent path; face-support gaps as WARN, 1,205 here) PASSED (ed713acd). Native element-time definition and short-shot state still unverified. Descriptive normalised pattern comparison, Moldex3D Run 02 vs Greif's Moldflow 2023 field (t/t_fill per tet, volume-weighted; scores ae441297): relative L2 **11.4 %**, last-fill centroid distance 10.5 % of the diagonal (Moldex3D has 62 exact ties at the maximum). Material substituted (Celstran PP-GF30-03 vs Factor PP GF 30; Factor not in the Moldex3D library). CORRECTION (MeltWin, same day): Run 02 already used Greif's process (270/45 °C, 0.05 s nominal flow-rate control, V/P at 98 % volume), and the approved re-solve reproduced the element CSV byte-identically (b7658acf) — so nominal process partly aligned (temperatures and nominal flow clock match; V/P differs: Greif actual 99.651 % / 50.7 ms vs Moldex3D 98 % volume), material substituted. Fill end still differs: Moldex3D .0598 s vs Moldflow .0510 s. **Why it matters:** if a matched solve (approved, MeltWin) still differs by ~10 %, two commercial solvers disagree by more than H2's ~6.7 % error against one of them, and a ~5 % target must be read against that.