diff --git a/docs/claude/research-tree.md b/docs/claude/research-tree.md index 081467e56..db90a9e88 100644 --- a/docs/claude/research-tree.md +++ b/docs/claude/research-tree.md @@ -34,6 +34,7 @@ Rules: | P3 | O1 with size-matched K = 8 partitions | — | — | PRUNED (eligibility 23 %; lesson: control cut area as a covariate, do not match it) | Log (newest first): +- 2026-11-23: **Greif 778 cross-solver supplement (learning part re-read once; arrays 0dbef32c, scores 100626b9).** Raw-seconds relative L2 **22.1 %** (normalised 11.4 %); fill end 59.82 vs 51.00 ms (+8.82 ms, +17 %); last-1 % physical-volume regions: centroid distance **.39 mm = 1.3 % of the diagonal** (the earlier 3.1 mm was a single-max tie artefact). **Reading (one part; V/P differs; material substituted):** the two solvers agree on WHERE the part fills last, differ by ~17 % in total fill time and ~11 % in normalised filling pattern. Not a general solver-disagreement floor; a second part would be needed before using it as one. - 2026-11-23: **Moldex3D route + first cross-solver look (Greif 778, fold-0 learning part).** Single approved Moldex3D Fill solve (Run 02, project's saved condition) → per-element arrival CSV for all 142,306 original tets; checker v3 FAILED on two node-rule carry-overs; v3.1 (gate = inlet-face tets; hard rule = every tet reaches the inlet along a non-decreasing vertex-adjacent path; face-support gaps as WARN, 1,205 here) PASSED (ed713acd). Native element-time definition and short-shot state still unverified. Descriptive normalised pattern comparison, Moldex3D Run 02 vs Greif's Moldflow 2023 field (t/t_fill per tet, volume-weighted; scores ae441297): relative L2 **11.4 %**, last-fill centroid distance 10.5 % of the diagonal (Moldex3D has 62 exact ties at the maximum). Material substituted (Celstran PP-GF30-03 vs Factor PP GF 30; Factor not in the Moldex3D library). CORRECTION (MeltWin, same day): Run 02 already used Greif's process (270/45 °C, 0.05 s nominal flow-rate control, V/P at 98 % volume), and the approved re-solve reproduced the element CSV byte-identically (b7658acf) — so nominal process partly aligned (temperatures and nominal flow clock match; V/P differs: Greif actual 99.651 % / 50.7 ms vs Moldex3D 98 % volume), material substituted. Fill end still differs: Moldex3D .0598 s vs Moldflow .0510 s. **Why it matters:** if a matched solve (approved, MeltWin) still differs by ~10 %, two commercial solvers disagree by more than H2's ~6.7 % error against one of them, and a ~5 % target must be read against that. - 2026-11-23: **Persistent late pockets, fold 0 (prebinding 8ea96b3b, scores 851e92dc, used holdout, descriptive; arrival-field topology, not air traps).** H2 / GBRT-19: count error .74 / .80 (Δ −.06 [−.26, +.14]); recall within 2 % diagonal 50.1 % / 38.6 % (Δ +11.5 pp [−2.5, +26.6], 79 parts / 24 families with ≥1 true pocket); spurious pockets per part 1.53 / 1.79 (Δ −.26 [−.66, +.08]). **Reading:** a ~6.7 % relative-L2 arrival field still finds only about half the true secondary late pockets and adds ~1.5 spurious ones per part — field accuracy does not imply topology accuracy. H2 is not established better than trees here. Any smoothing/readout variant (e.g. k4) would be post hoc on this holdout; a topology-aware target needs a fresh evaluation set (Moldex3D parts once the export works). - 2026-11-23: **Seed noise of arm A (P/T), folds 1–3 (prebinding 14b347b9, used holdouts, descriptive).** s1 − s0 relative L2: P −2.29 pp [−9.45, +4.01], +2.32 pp [−11.10, +18.89], +2.69 pp [−4.70, +11.13]; T −.07 / −.18 / +.12 pp, all CIs span 0. **Reading:** seed-to-seed pressure shifts are ~±2–3 pp at the point estimate, so arm S's −7.4 / −11.7 pp on folds 1–2 are larger than one seed swap, but fold 3 (+.9 pp) and the T guard keep S 'not established'. Per-fold pressure CIs are ±7–17 pp wide, so single-fold pressure tests are low-powered. **Rule for future P tests:** prebind a fold-pooled statistic (family-paired bootstrap over all folds' families) as primary, with per-fold signs descriptive.