Supersedes 71221837. Samples every t* 0.5 (interval-mean forces), trailing
t* 50..60 window (21 samples); range <= 10 % and |slope*window| <= 2 % of
each official band width. Verdict on the window mean with the distance to
the nearest band edge. Our engineering rule, frozen before any run.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit 869d60d78e)
Samples every 0.5 s at synchronized root steps; trailing 5 s window (11
samples); range and |slope*window| each at most 1 % of the official band
width. States the fluid-on-cylinder force sign, reports cd_positive,
defaults to the refined case and uses the review's label.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit 71221837f9)
Reuses the pinned Re100 runner and helpers unchanged; sets only the
lattice viscosity for Re 20. Reports Cd, Cl and p_diff (dp * 0.04 for
U = 0.2 m/s), a steady rule frozen before any run (window ranges at most
a tenth of each official interval width) and no interval verdict when
not steady. Declares the pressure-NEQ outlet and Zou-He inlet deviations.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
(cherry picked from commit 9b8ff90609)