docs: Dütsch protocol — fold the closed domain order, settling rule, window and criteria

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
ClaudeandClaude Opus 5.5 committed 2026-10-30 10:44:38 +00:00
1 parent cd73fcd689
commit 10cea29e8e
1 file changed
+70 -56
+70 -56
View File
@@ -71,17 +71,24 @@ fixed before any benchmark result; it is not a paper uncertainty.
## 3. Domain and boundaries (finite-domain reproduction), ENGINEERING ## 3. Domain and boundaries (finite-domain reproduction), ENGINEERING
- Boundary family (runner owner confirms the zero-velocity inlet is supported The paper's 120 D O-grid is not reproduced; our rectangular box is a
as configured before any run): the native dense channel only — zero-velocity inlet, reproduction choice. The native dense channel (zero-velocity inlet,
pressure-NEQ outlet, y walls (bounce-back). This is a finite-domain pressure-NEQ outlet, bounce-back y walls) is a finite-domain approximation,
approximation of the paper's 120 D O-grid, NOT infinite still fluid. The G4 not infinite still fluid. The G4 x-periodic / y-slip override is a separately
periodic/slip overrides are a different family and are not substituted. labelled sensitivity family and never mixed into the primary ladder. The
- Sensitivity order (each step at D = 40 before the ladder is run): runner owner confirms the zero-velocity inlet is supported as configured
1. box 24 D × 24 D vs 48 D × 48 D (cylinder mean position at the centre); before any run.
2. the larger box is accepted if section 6 domain criteria pass between the
two; otherwise 96 D is tried once (memory/runtime measured first); if that Order (closed):
still fails, the domain verdict is FAIL and is reported. 1. Smoke + ledger at D = 40, native BC, 40 D × 40 D (finite box).
- The ladder (D = 20 / 80) uses the accepted box size in units of D. 2. Domain sensitivity before any literature statement: same BC, D = 40,
L ∈ {20 D, 40 D, 60 D}; record the change in Fx waveform, c_d, c_i and the
scored profiles.
3. Optional labelled BC sensitivity: one x-periodic / y-slip case at D = 40,
40 D; reported as a delta against native only.
4. Only after step 2 passes: the D = 20 / 40 / 80 ladder on the chosen BC and
domain (default 40 D if, against 60 D, `RMS(dFx)/F_ref` and |dc_d|, |dc_i|
stay inside the section 6 bands).
- Memory/runtime: measured by a smoke run before each new size; measurements - Memory/runtime: measured by a smoke run before each new size; measurements
inform scheduling only, never tolerances. inform scheduling only, never tolerances.
@@ -91,68 +98,75 @@ fixed before any benchmark result; it is not a paper uncertainty.
CME + Wen and CME + cover − uncover reported separately; crossings, eq_only, CME + Wen and CME + cover − uncover reported separately; crossings, eq_only,
no_donor (no_donor must stay 0). no_donor (no_donor must stay 0).
- Velocity u1, u2 on lab-fixed lines x/D = -.6, 0, .6, 1.2 (relative to the - Velocity u1, u2 on lab-fixed lines x/D = -.6, 0, .6, 1.2 (relative to the
mean cylinder position) versus x2, at every step of the scored phases. mean cylinder position) versus x2, at the scored phases. Lab frame
throughout; if any body-frame intermediate is used, position and velocity
are both transformed.
- Interpolation: bilinear on cell centres using only cells that are fluid at - Interpolation: bilinear on cell centres using only cells that are fluid at
that step (flags read back via `get_flags()`); weights renormalized over the that step (flags read back via `get_flags()`); weights renormalized over the
fluid corners; a sample with no fluid corner, or inside the circle at that fluid corners; a sample with no fluid corner, or inside the circle at that
step, is MISSING and logged, never set to zero. One-degree bins carry only step, is MISSING and logged, never set to zero. One-degree bins keep valid
valid samples. fluid weights. The numerical average need not mimic the 200 LDA samples.
## 5. Periodic-regime gate (every case, before any statistic) ## 5. Periodic-regime gate (every case, before any statistic), ENGINEERING
Ledger rows, same schema for every case: Ledger rows, same schema for every case: dx, dt (in D and T units); U_max, nu,
Re, KC (lattice and nondimensional); T (native steps, nondimensional);
duration (native steps, s/T, paper cycles); discard; accepted window; cycle
ledger; verdict PASS or FAIL-CLOSED.
| field | content | Scales: `F_ref = 0.5 rho U_max² D`, `U_ref = U_max`; never a near-zero mean
|---|---| force as denominator.
| dx, dt | in D and in T units |
| U_max, nu, Re, KC | lattice and nondimensional |
| T | native steps and nondimensional time |
| duration | native steps, s/T, number of paper cycles |
| discard | cycle 0 plus all cycles before the accepted window |
| window | the common accepted window (below) |
| cycle ledger | per cycle k: phase-aligned waveform change and profile change (below) |
| verdict | PASS or FAIL-CLOSED |
- Settling metric, ENGINEERING, fixed scales (no near-zero denominators): - Settling metrics, cycle k−1 → k, phase-aligned by step within the cycle:
- force: `max over phase of |F_k(phi) - F_{k-1}(phi)| / (0.5 rho U_max² D)` - waveform `RMS(dFx) / F_ref ≤ .02`;
on the per-step CME waveform aligned by step index within the cycle; - `|d mean|`, `|d RMS|`, `|d peak|` of Fx, each `/ F_ref ≤ .01`;
- profiles: `max over scored stations/phases/points of |u_k - u_{k-1}| / U_max`. - scored profiles (fluid-only) `|du| / U_max`, `|dv| / U_max ≤ .03` at the
- Rule: K_case = the smallest cycle k ≥ 4 for which both metrics are ≤ .005 three phases × four stations;
for the N = 3 consecutive pairs (k-3→k-2), (k-2→k-1), (k-1→k). - Morison `|dc_d| ≤ .02`, `|dc_i| ≤ .02`.
- Cap: 30 paper cycles per case; not settled by the cap → FAIL-CLOSED. - Rule: all metrics for N = 3 consecutive whole paper cycles → settled.
- Common window: K = max over all compared cases of K_case; every case is run - Discard: the initial quarter cycle plus the first 2 full paper cycles
to cycle K + 2 and scored on cycles K, K + 1, K + 2 (same indices). (s/T < 2.25). Settling is searched from cycle 3; cap 12 periods from s = 0;
- FAIL-CLOSED also if any case covers fewer paper cycles than K + 2, if windows unsettled → FAIL-CLOSED (no literature, cross-resolution or VIV statistic).
differ, or if the ledger is missing. - Common window: K = the largest first-settled cycle index over all compared
cases; every case is scored on the same 3 cycles K .. K + 2 and must reach
them within the cap (proportionally more native steps on finer grids), or
the comparison is FAIL-CLOSED.
- The earlier G4 timing check (100 coarse vs 400 diffusive-fine steps) was a - The earlier G4 timing check (100 coarse vs 400 diffusive-fine steps) was a
matched short transient, not periodic evidence. matched short transient, not periodic evidence.
## 6. Metrics and per-observable criteria (ENGINEERING, not paper uncertainty) ## 6. Metrics and per-observable criteria (ENGINEERING, not paper uncertainty)
Three criteria stay separate; the G4 same-grid 2% target is not reused.
- Morison fit: least squares of the normalized per-step force over the - Morison fit: least squares of the normalized per-step force over the
accepted window against the two basis functions above, each averaged over accepted window against the two basis functions, each averaged over its
its single step interval, fixed paper phase, no free phase shift; outputs single step interval, fixed paper phase, no free phase shift; c_d and
c_d and added-mass c_i per force candidate. added-mass c_i per force candidate.
- Criteria: - Cross-resolution: every scored observable's error against its reference must
- cross-resolution: for each observable, the D20→D40→D80 differences to decrease monotonically D20 → D40 → D80 (necessary, not sufficient).
D80 must decrease; force waveform: normalized RMS difference D40 vs D80 - Against Table 1 (computed fit, not measured force): at D ≥ 40,
≤ .02 (scale `0.5 rho U_max² D`); profiles: RMS D40 vs D80 ≤ .02 U_max; `|c_d - 2.09| ≤ .15` and `|c_i - 1.45| ≤ .15`, and monotone.
- domain (section 3): same two norms ≤ .01 between the two box sizes; - Force waveform against its own Morison reconstruction: residual reported
- against Table 1 (computed reference): |c_d - 2.09| ≤ .06 and only, no pass/fail (the paper reports fit error above its coarse numerical
|c_i - 1.45| ≤ .04 at D = 80 (our engineering bands; the table's own error and gives no percentage).
96→384 change is reported alongside, not used as an error bar); - Fig. 8 LDA profiles: QUALITATIVE ONLY. The original figure could not be
- against Fig. 8 LDA: QUALITATIVE ONLY. The original figure could not be accessed or rendered; no digitized ordinates and no measurement uncertainty
accessed or rendered (TRON 2026-10-30); no digitized ordinates and no exist. After a digitization with figure number, tool and uncertainty note:
measurement uncertainty exist. No quantitative profile pass is claimed. `RMS(|du|, |dv|) / U_max ≤ .15` at D ≥ 40 and monotone; LDA error stays
A quantitative criterion may be declared only after an accessible original UNQUANTIFIED and is stated with every comparison.
figure or data set and a documented digitization (figure, tool, - Fy sanity (not literature): `|mean Fy| / F_ref ≤ .05` in the accepted window.
uncertainty) exist, and before that comparison is run.
- No force candidate is selected for an RHS by these results; each is - No force candidate is selected for an RHS by these results; each is
reported. reported.
Superseded (earlier drafts): the velocity-jump start, guessed stations and
phases, "C_M" for c_i, and the uncertainty wording; cycles 4–6, the 30-cycle
cap and the earlier tolerance numbers.
## 7. Order and scope ## 7. Order and scope
Protocol review → lean test driver (no production change; reuses the Protocol review → one-shot Dütsch driver (analytic `set_body` + `run(1)`,
existing Simulation API) → smoke (memory/runtime) → domain sensitivity → cycle ledger, lab-fixed fluid-only station sampler, two-basis Morison fit; no
reusable runner until the first smoke shows shared helpers pay off; no
production change) → smoke (memory/runtime) → domain sensitivity →
ladder → physical-validation verdict → only then single-cylinder VIV. No AMR, ladder → physical-validation verdict → only then single-cylinder VIV. No AMR,
no pinball, no manuscript work. no pinball, no manuscript work.